久久久国产精品无码免费专区,大鸡巴狂插小穴流水视频,无码人妻精品一区二区蜜桃在线看,欧美黄片在线看

您的位置: 首頁 > 技術(shù)文章 > Acrel anti-backflow meter apply in the Philippines photovoltaic project

Acrel anti-backflow meter apply in the Philippines photovoltaic project

更新日期:2021-11-09瀏覽:676次

1.Background

    With the development of photovoltaic industry, the capacity of village-level transformers and industrial power transformers and the installed capacity of photovoltaic projects are saturated in some areas.The power grid company requires the photovoltaic grid-connected system to be a non-backflow current generation system, which means that the electricity generated by the photovoltaic grid-connected system is consumed by the local load, and the excess electricity is not allowed to be sent to the upper power grid through the low-voltage distribution transformer in reverse direction.

    Photovoltaic inverter in photovoltaic components will produce direct current into alternating current (ac), has the dc component and harmonic mixing, unbalanced three phase current, output power of uncertainty, such as the current basic didn't take effective management measures, therefore, when there is power to the utility grid, will generate harmonic pollution to power network, easy cause power grid voltage fluctuation and flicker, etc.,If there are many such power sources to transmit electricity to the grid, the power quality of the grid will be seriously degraded.Therefore, this kind of photovoltaic power generation system must be equipped with anti-backflow current facilities to prevent the occurrence of reverse power.

    When the photovoltaic power generation is greater than the load demand, the inverse power will be generated.So we need instruments to determine that Inverter has power output, and then by the instrument through RS485 communication signal and inverter data interaction, adjust the inverter output power, so that its output power and power balance.

2.Project Overview

    A photovoltaic power generation company in the Philippines contacted our company to look for anti-backflow current meters. After proper connection agreement, we will purchase ACR10R-D16TE from our company.

3.Anti-backflow detection meter

    When the photovoltaic power generation is greater than the load demand, reverse power will be generated. Therefore, we need an meter to determine that the inverter has over-power output, and then the meter sends a signal through RS485 communication to interact with the inverter data to adjust the output power of the inverter to balance the output power and the electrical power.

1.png

4.Function 

2.png

4.png

5.Wiring


6.Typical Connection

7.png

Bibliography

1.Solutions for enterprise micro-grid system 


 

Contact Us
  • 郵箱:2885080326@qq.com
  • 地址:上海市嘉定區(qū)育綠路253號

掃一掃  微信咨詢

©2025 安科瑞電氣股份有限公司 版權(quán)所有    備案號:滬ICP備05031232號-79    技術(shù)支持:智慧城市網(wǎng)    Sitemap.xml    總訪問量:221836    管理登陸

電瓶車充電樁禁止非法改裝

绿春县| 武清区| 徐闻县| 呼伦贝尔市| 专栏| 宁远县| 泸溪县| 云和县| 工布江达县| 泸西县| 体育| 应城市| 乳源| 桐庐县| 沂源县| 东安县| 钟山县| 合山市| 江油市| 九寨沟县| 三穗县| 巴马| 松桃| 陇川县| 达日县| 关岭| 县级市| 盐源县| 蓝山县| 蚌埠市| 麻阳| 彭山县| 凤台县| 涞源县| 贺州市| 康平县| 怀集县| 澜沧| 南昌市| 惠水县| 柳林县|